RT-...AK | flow transducer

Product.Nr.: RT-...AK

Manufacturer: Senseca (ehemals Honsberg)

  • delivery time resp. manufacturing period varies - upon request!

product description

Formerly known as "Rototron"
 
General information:

A turbine functions as primary sensor. Its rotational speed is proportional to the flow rate. The rotational speed is detected by a biased Hall sensor, this means there are no magnets in the flow space.

 
  • High accuracy
  • No magnetic components in the flow space
  • High pressure resistance
  • Low pressure loss

Specifications:
 
Appliance: flow, measurement
Medium: water (oil up to 5 mm²/s and aggressive media upon request)
Total measuring range: 1.8 l/min to 1133 l/min H2O
Connection: G 1/2 A to G 2 A external thread, stainless steel
Basic data: PN 250 bar, temperature of medium -20°C to +85°C,
optionally -20°C to +150°C (for 8 bar min.)
Electrical data: biased Hall sensor
supply voltage 10 V DC to 30 V DC



With integrated evaluation electronic available in the following construction types:

LABO-RT: evaluation electronic with analog output or switching function incl.
FLEX-RT: evaluation electronic with analog output and switching function incl.
OMNI-RT: evaluation electronic with analog output, switching function and display incl.

Downloads