LABO-RT-I/U/F/C with RT-... | flow transducer
Product.Nr.: LABO-RT-IUFC
Manufacturer: Senseca (ehemals Honsberg)
product description
General information:
A turbine functions as primary sensor. Its rotational speed is proportional to the flow rate. The rotational speed is detected by biased Hall sensors, this means there are no magnets in the flow space.
The LABO electronics provide various output signals:
- Analog signal 0/4 mA to 20 mA (LABO-RT-I)
- Analog signal 0/2 V to 10 V (LABO-RT-U)
- Frequency signal (LABO-RT-F) or
- Flow signal pulse / x litre (LABO-RT-C)
A model with switching output is also available.
If desired, the range end value can be set to the currently existing flow using "teach-in".
- High accuracy
- No magnetic components in the flow space
- High pressure resistance
- 0...10 V, 4...20 mA , frequency and pulse output completely configurable
Specifications:
Appliance: | flow, measurement |
Medium: | water (oil up to 5 mm²/s and aggressive media upon request) |
Total measuring range: | 0.11 m³/h to 68 m³/h H2O |
Connection: | G 1/2 A to G 2 A external thread, stainless steel |
Basic data: | PN 250 bar, temperature of medium -20°C to +85°C, optionally -20°C to +150°C (for 8 bar min.) |
Electrical data: | biased Hall sensor, supply voltage 10 V DC to 30 V DC |